PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch

Product Details
Customization: Available
Accuracy: ±0.2-0.5%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Still deciding? Get samples of US$ 380/Piece
Request Sample
Manufacturer/Factory & Trading Company
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
600 square meters
Management System Certification
ISO9001:2015
  • PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch
  • PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch
  • PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch
  • PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch
  • PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch
  • PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch
Find Similar Products

Basic Info.

Model NO.
HDF-DC
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electromagnet Flow Meter
Measurement Object
Closed Pipeline
Certification
DIN, CE, RoHS, ISO
Name
Electromagnet Flow Meter
Connection Size
DN10-DN2000mm
Medium
Conductive Fluids
Output
4-20mA or Pulse Output, RS485
Supply Power
AC220V, DC12-24V or Lithium Cell Batery
Electrode Material
SS316L, Hastelloy B, Hastelloy C, Titanium, Tantal
Explode-Proof Class
Exdiibt4
Protection Class
IP65, IP68
Transport Package
Negotiation
Specification
9.50Kg 28*28*40cm
Trademark
Huadian Automation
Origin
China
HS Code
9026100000
Production Capacity
1000pieces

Product Description

PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch

        HDF-DC electromagnetic flowmeter can be used to measure the volume flow of conductive fluid in a closed pipeline. It is widely applied in the flow measurement and control in the fields of chemical and petroleum industry, metallurgy industry, water and wastewater, agriculture and irrigation, paper making, food and beverage industry and pharmaceutical industry, etc.

       When the conductive fluid flows through the measuring tube of the sensor, the voltage signal in direct proportion to the average flow velocity of the fluid will be inducted on the electrodes. The signal is amplified and treated by the transmitter to realize various display functions.

PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch
1) Flange Type                        2) Tri-clamp Type                  3) Remote Type                   
  4) Insertion Type

Technical Parameters: 
Product name Electromagnetic flow meter 
Nominal Diameter(mm) DN10-DN2000mm
Medium Conductive fluids
Accuracy Class 0.5%F.S
Electrode material SS316L, Hastelloy B, Hastelloy C, Titanium, Tantalum and platinum-iridium alloy, etc. 
Medium Temperature  Medium:-20~120ºC     
Connection Insertion, Flange, Tri-clamp, Remote 
Signal Output 4-20mA or pulse output, RS485
Supply Power AC220V, DC12-24V or Lithium cell Battery
Fluid conductivity ≥ 5 uS/cm
Explode-proof Class ExdIIBT6
Protection Class IP65
Keywords Slurry Flow Transmitter 

PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch
PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch

 
Selection Table 
PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch
Electromagnetic Flow Meter Features
1) DN 6 to DN2000 covers a wide range of pipe size.
2) No obstacle in the pipe, no pressure-loss and lower requirement for straight pipeline.
3) RS485 or RS232 interface supports digital communication.
4) A variety of liners and electrodes are available to satisfy different flow characteristic
5) Easy to install and maintain
6) Flexible connection to flow instruments for flow control
7) Wide variety of process connections
8) Programmable low-frequency square wave field excitation, improving measurement stability and reducing power consumption.
9) High definition LCD display with backlight.


Installation
PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch
How to select the right Electromagnetic Flow Meter? 
The key questions which need to be answered before selecting a turbine flowmeter are:
1.what's the fluid?
2.what's flow range? and pipe size?
3.what's working pressure?
4.what's working temperature?
5.do you need display or not?

PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch

Why choose Huadian
1. Instruments have been exported to over 50 countries.
2.100% QC inspection Before Shippment.
3.ISO, CE, SGS standard and factory price.
4. All instruments have been 100% recognized by the Bureau of National  Metrology.
5.Excellent product quality and strong technical support capability.

 
Packaging & Shipping
PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch

Contact Us

Related Products
PTFE Liner Hastelloy Alloy Electrode Electromagnetic Flowmeter Hydrochloric Acid Flow Meter 4 Inch

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier